Generator Enclosure


Specifications

General

This is customised specification for fabrication of Weather proof Enclosure for generator and mounting of 1500 kVA Generator –Horzontal ( BUILT IN ) Exhaust On free issue 6x6 Chassis.

Construction

All welded steel construction to spec.ST-37-2, or equivalent unless otherwise specified.

Roof

Tapered roof made of 3 mm thick aluminium plate.

Sides

Side made of 3mm thick G.I. plate. There are access doors, Three on left hand side and two on right hand side and one at front leaf type. There are air intake louver type ventilator on both sides and rear.

Floor

6mm thick G.I. chequered plate.

Radiator Cover

Radiator cover is provided all around the radiator exhaust. The exhaust cover will be insulated form DG Unit side..

Base

Enclosure base made from I-beam approx. 300 mm with adequate cross members. At each corner of the enclosure corner casting are provided for the twist locks.

Sub frame

UPN 200x75 with 4 no’s cantilever beams for container twist lock and 8 no’s channels fixed to the sub frame for enclosure bolting.

Platform

Platform behind the cab with 3mm thick aluminium chequered plate and side fencing of 3/4” pipe to the platform with access ladder of either side.

Diesel Tank for Genset

Approx.2400-2800ltrs.Capacity diesel tank on base frame of the Genset with tank panel includes 2” vent pipe, 1” outlet / Inlet with ball valve, filling pipe 2” with dust cap & adaptor with flap door on LH side, level gauge for to indicate fuel level and drain pipe with ball valve at the bottom of the base frame.

Accessories

ØMudguard with mud flaps for rear wheels.

ØReflecting sign at rear.

ØSide marker lights 3 nos. on either side.

ØSide guard on both side.

ØContainer twist lock -4no’s.

ØLanding gear manually operated one pair at front and one pair at rear – ‘JOST’ Germany.

ØFixed ladder to access to top on front LH side.

Ø4 no’s. fluorescent roof light with one common switch.

ØOne 3 pin 16 amps industrial female socket at front.

ØFixing of LV terminal (LV terminal must come along with the genset).

ØBolted type steel box cover for LV terminal.

ØSkeleton type cable carrier made of pipe around the enclosure.

ØThermal Insulation for the piping and exhaust silencer.

Painting

Sand blasted to SA 2.5 standard and painted with one coat of primer plus two coats of synthetic finish paint, single colour RAL 1007, (DUPONT Imron 700) & sub frame in black colour to suit the chassis.